Bio-Pure Range
The Bio-Pure sewage treatment plant is available in 9 sizes to cater for up to 40 persons. The Bio-Pure 1-5 are single units and the Bio-Pure 6-9 are twin units.
There are several options available within the Bio-Pure range. The Bio-Pure, The Bio-Pure E Range and the Bio-Pure Pumped.
Bio-Pure
The standard Bio-Pure Sewage Treatment Plant with normal air pump(s).
Bio-Pure E Range
The Bio-Pure Sewage Treatment Plant with an economical air pump(s). The same power with
Bio-Pure Pumped
We manufacture the Bio-Pure to contain an integral pump. This will be used when your discharge point is at a higher level than the outlet from the Bio-Pure.
In order to work out which plant is suitable for your property you must abide by the British Water Code of Practice: Flows and Loads-2 Sizing Criteria, Treatment Capacity for Small Wastewater Treatment Systems (Package Plants) (BW COP: 1/05). The table of loadings set out the suitable sizes of treatment plants for different types of property.
A domestic dwelling is fairly straightforward to work out. This is usually the number of bedrooms in the property plus two. For example, a three bedroom house becomes five (requiring a Bio-Pure 2). However, if the treatment plant is required for more than one property, then two must added to each dwelling. For example, a three bedroom house plus two = five, a two bedroom house plus two = four and a four bedroom house plus two = six, will become fifteen (5+4+6). This will require a Bio-Pure 5.
For a non- residential property, the size Bio-Pure required will depend on the purpose of the property. Please contact us and we will be able to work out the correct size Bio-Pure required for your needs.
Technical Specifications of the Bio-Pure Range
|
Bio-Pure |
Bio-Pure |
Bio-Pure |
Bio-Pure |
Bio-Pure |
Bio-Pure |
Bio-Pure |
Bio-Pure |
Bio-Pure |
|
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
9 |
| No. of persons |
1 to 4 |
1 to 6 |
5 to 12 |
10 to 15 |
14 to 20 |
20 to 26 |
25 to 31 |
30 to 35 |
35 to 40 |
|
|
|
|
|
|
|
|
|
|
| Max. average daily flow |
800 ltr |
1200 ltr |
2400 ltr |
3000 ltr |
4000 ltr |
5200 ltr |
6200 ltr |
7000 ltr |
8000 ltr |
|
|
|
|
|
|
|
|
|
|
| Max. BOD/day |
240 g |
360 g |
720 g |
900 g |
1.200 g |
1.560 g |
1.860 g |
2.10 g |
2.40 g |
|
|
|
|
|
|
|
|
|
|
| In ground depth |
2.25 m |
2.25 m |
2.44 m |
2.74 m |
2.74 m |
1 x 2.25 m |
2 x 2.74 m |
2 x 2.74 m |
2 x 2.74 m |
|
|
|
|
|
|
1 x 2.74 m |
|
|
|
|
|
|
|
|
|
|
|
|
|
| Outside Diameter |
1.85 m |
1.85 m |
2.10 m |
2.10 m |
2.10 m |
1 x 1.85 m |
2 x 2.10 m |
2 x 2.10 m |
2 x 2.10 m |
|
|
|
|
|
|
1 x 2.10 m |
|
|
|
|
|
|
|
|
|
|
|
|
|
| Inlet invert |
570 mm |
570 mm |
700 mm |
700 mm |
700 mm |
700 mm |
700 mm |
700 mm |
700 mm |
|
|
|
|
|
|
|
|
|
|
| Outlet invert |
670 mm |
670 mm |
800 mm |
800 mm |
800 mm |
900 mm |
900 mm |
900 mm |
900 mm |
|
|
|
|
|
|
|
|
|
|
| Weight empty |
125 kgs |
125 kgs |
200 kgs |
230 kgs |
230 kgs |
355 kgs |
460 kgs |
460 kgs |
460 kgs |
|
|
|
|
|
|
|
|
|
|
| Total capacity |
2270 ltr |
2270 ltr |
3000 ltr |
3975 ltr |
3975 ltr |
6245 ltr |
7950 ltr |
7950 ltr |
7950 ltr |
|
|
|
|
|
|
|
|
|
|
Power consumption For Bio-Pure |
60 w |
80 w |
110 w |
160 w |
220 w |
300 w |
360 w |
380 w |
440 w |
|
|
|
|
|
|
|
|
|
|
Power consumption For E Range |
32 w |
45 w |
64 w |
90 w |
140 w |
185 w |
210 w |
230 w |
280 w |